    Spray polyurea waterproof material is composed of raw materials such as prepolymers, polyetheramines, and amine chain extenders, and is formed by on-site spraying of polyurea elastomers. This technology organically combines new materials, new equipment, and new processes, making it a revolutionary leap forward in traditional construction techniques.

    Scope of application

    Mainly used for waterproofing in fields such as water conservancy engineering, buildings, tunnels and bridges, sports venues, amusement facilities, underground engineering, and power plant cooling towers.

    Product feature:

    1. Solvent free, environmentally friendly
    2. Fast curing speed, continuous spraying, no sagging
    3. The coating is dense and seamless, with excellent waterproof performance
    4. High elongation, no cracking or detachment during cold and hot alternation
    5. Good weather resistance and no powdering

    Main performance indicators of spray polyurea waterproof material (type II):

    Item

    Type II

    Actual measurement value

    Testing standards

    Hardness Shao A ≥

    80

    85

    Shao A hardness tester

    Solid content (%), ≥

    98

    98

    GB/T 1725-2007

    Gel time (s), ≤

    45

    12

    GB/T 1728-2020

    Tensile strength (MPa), ≥

    16

    17.5

    GB/T 528-2009

    Elongation at break (%), ≥

    450

    532

    GB/T 528-2009

    Tear strength (KN/m), ≥

    50

    73

    GB/T 529-2008

    Adhesion (concrete)(MPa), ≥

    2.5

    3.5

    GB/T 16777-2008

    Impact resistance (kg·m), ≥

    1

    2.5

    GB/T 20624.2-2006

    Water impermeability (0.4MPa, 2h)

    impermeable

    impermeable

    GB/T 23446-2009

    Wear resistance [(750g/500r)/mg], ≤

    30

    25

    GB/T 23446-2009

    Alkali treatment (saturated alkali solution), 7d

    Tensile strength retention rate /%

    80-150

    93

    GB/T 16777-2008

    Elongation at break /%≥

    400

    508

    Low temperature flexability /-30℃≤

    -35

    -35 No cracks

    Acid treatment (2% sulfuric acid solution), 7d

    Tensile strength retention rate /%

    80-150

    91

    GB/T 16777-2008

    Elongation at break /%≥

    400

    497

    Low temperature flexability /-30℃≤

    -35

    -35 No cracks

    Salt treatment (3% sodium chloride solution), 7d

    Tensile strength retention rate /%

    80-150

    95

    GB/T 16777-2008

    Elongation at break /%≥

    400

    532

    Low temperature flexability /-30℃≤

    -35

    -35 No cracks

    Artificial climate aging, 720h

    Tensile strength retention rate /%

    80-150

    89

    Elongation at break /%≥

    400

    456

    Low temperature flexability /-30℃≤

    -35

    -35 No cracks

    flexability /-30℃≤

    Note: The above parameters are the physical properties tested after 7 days of curing with 25±2℃ relative humidity of 50%± 5% after spraying under standard conditions with domestic host and domestic spray gun.

    Construction instructions:

    Mix component B thoroughly until completely uniform before construction; A/B ratio: A: B=1:1 (volume ratio);

    It is recommended to use the high-temperature and high-pressure impact mixing equipment designated by our company during construction;

    Coating thickness: 1-2mm (depending on user requirements); Theoretical coating rate: 1.1kg/m2/mm;

    Painting interval: The shortest time is not limited, and the longest time should not exceed 18 hours (temperature 25 ℃, humidity 50%)

    Note: Coatings of component A that have not been used up should be sealed and stored after nitrogen filling; This system is solvent-free and it is strictly prohibited to add any diluent.

    Drying time:

    Surface dryness: ≤ 1 minute, walking intensity can be achieved within 10 minutes (temperature 25 ℃, humidity 50%).

    Construction conditions:

    During construction, the substrate temperature should be at least 3 ℃ higher than the dew point, and the environmental humidity should be ≤ 90% RH. Good ventilation should be ensured during construction in enclosed spaces.

    Main performance indicators of spray polyurea waterproof material (type I):

    Item

    Type I

    Actual measurement value

    Testing standards

    Hardness Shao A ≥

    70

    75

    Shao A hardness tester

    Solid content (%), ≥

    96

    98

    GB/T 1725-2007

    Gel time (s), ≤

    45

    12

    GB/T 1728-2020

    Tensile strength (MPa), ≥

    10

    12.5

    GB/T 528-2009

    Elongation at break (%), ≥

    300

    375

    GB/T 528-2009

    Tear strength (KN/m), ≥

    40

    58

    GB/T 529-2008

    Adhesion (concrete)(MPa), ≥

    2

    3.5

    GB/T 16777-2008

    Impact resistance (kg·m), ≥

    0.6

    2.5

    GB/T 20624.2-2006

    Water impermeability (0.4MPa, 2h)

    impermeable

    impermeable

    GB/T 23446-2009

    Wear resistance [(750g/500r)/mg], ≤

    40

    30

    GB/T 23446-2009

    Alkali treatment (saturated alkali solution), 7d

    Tensile strength retention rate /%

    80-150

    93

    GB/T 16777-2008

    Elongation at break /%≥

    250

    322

    Low temperature flexability /-30℃≤

    -30

    -35 No cracks

    Acid treatment (2% sulfuric acid solution), 7d

    Tensile strength retention rate /%

    80-150

    91

    GB/T 16777-2008

    Elongation at break /%≥

    250

    317

    Low temperature flexability /-30℃≤

    -30

    -35 No cracks

    Salt treatment (3% sodium chloride solution), 7d

    Tensile strength retention rate /%

    80-150

    95

    GB/T 16777-2008

    Elongation at break /%≥

    250

    327

    Low temperature flexability /-30℃≤

    -30

    -35 No cracks

    Artificial climate aging, 720h

    Tensile strength retention rate /%

    80-150

    89

    GB/T 16777-2008

    Elongation at break /%≥

    250

    295

    Low temperature flexability /-30℃≤

    -30

    -35 No cracks

    Note: The above parameters are the physical properties tested after 7 days of curing with 25±2℃ relative humidity of 50%±5% after spraying under standard conditions with domestic host and domestic spray gun.